11
The hob should be connected to a double pole switch
with a minimum gap of 3 mm. between the switch
contacts and of a type suitable for the required load in
compliance with the current electric regulations. The
switch should be sited within 2m of the hob and be easily
accessible upon completion of the installation.
The switch must not break the yellow and green earth
cable at any point.
Ensure that the hob supply cord does not come
into contact with surfaces with temperatures
higher than 50 deg. C.
FO 0488
Supply Cable Specifications
Connection Min. size Cable / flex Fuse
via Cable/flex type
• Cooker 6 mm
2
PVC/PVC 30 A
Control twin and
Circuit earth
For Uk use only
For Europe use only
Min. size Cable/flex Cable / flex type Fuse
2.5 mm
2
H05 RR-F / H05V2V2
20 A
H05 BB-F
Wiring diagram